■Output variables
Name
Completion
Executing
Controlling
Abortion of execution
Error
Error code
6 AXIS CONTROL FUNCTION
206
6.4 Multiple Axes Positioning Control
Variable name
Data type
Done
BOOL
Busy
BOOL
Active
BOOL
CommandAborted
BOOL
Error
BOOL
ErrorID
WORD (UINT)
Default
Description
value
FALSE
Indicates that the control is completed.
When Execute is TRUE at the operation
completion, TRUE remains until Execute turns
FALSE.
When Execute is FALSE at the operation
completion, it becomes TRUE only for one cycle.
FALSE
Indicates that the FB is in execution.
FALSE
Indicates that the axis is being controlled. When
multiple FBs are executed for the same axes
group, Active of only one FB turns TRUE.
FALSE
Indicates that execution of FB has been aborted
due to error or multiple start.
FALSE
Indicates that an error has occurred.
0000H
The generated error code is returned.
For details, refer to the following.
Page 534 List of Error Codes