[Setting the target position exceeding the ring counter (Options bit16)] "1: Allow"
The positioning operation that overflows the ring counter upper limit value can be performed. In this case, the ring counter
upper limit value is used as a reference, and positioning is performed with the amount of movement exceeded as the relative
movement amount. If the target position is set with the value smaller than the ring counter lower limit value, positioning does
not start for the error "Out of Ring Counter Range" (error code: 1AA3H).
Setting
• Current value  Target position < Ring
counter upper limit value
• Ring counter lower limit value  Target
position < Current value
Ring counter upper limit value  Target
position < Positioning range upper limit
value
6 AXIS CONTROL FUNCTION
178
6.1 Single Axis Positioning Control
Operation
The same operation as the "Setting the Target position exceeding the ring counter: Not allow"
Positioning range
upper limit value
Current value "0"
Ring counter
100
upper limit value
0
Ring counter
-100
lower limit value
Ring counter
upper limit value "100"