Auto logging
When inserting an SD memory card, which holds logging setting, into the motion system, the data logging automatically starts
based on the logging setting information on the SD memory card.
(3) Logging
Factory
■How to use auto logging
The following describes how to use auto logging.
1.
Set System.PrConst.Logging_AutoLoggingEnable to TRUE in advance and allow the auto logging function.
2.
Write the following logging setting file. Set /sdc/LOGGING□□.json or /sdc/LOGGING/LOG□□/LOGGING.json(□□ = 01 to
10) to the writing destination. (When there are both files, the priority is the former.)
Logging start conditions is set as "Starts automatically".
3.
Start the system by inserting the SD memory card prepared in step 2 into the Motion module or insert the Motion module
while it is running.
4.
System.LoggingRef[1..10].Cd.SettingPath which corresponds to the logging setting file stored in the SD memory card
automatically becomes the path of the setting file, System.LoggingRef[1..10].Cd.StartLog becomes TRUE and logging
starts. If the logging setting of that number already operates, a new logging does not start and an error occurs. (The
logging which has already started is not affected.)
(1) Set loggings including auto-logging setting
to SD memory card.