Logging setting

The following describes how to set data logging/real-time monitor.
The ( ) of the title indicates the object name of logging setting files (Json format) in this below.

Data to be collected (DATA)

Set data to be collected by logging. The number of data can be set is up to 1024.
Duplicate data records are counted as distinct.
Data name (NAME)
Set the data name to be collected (device, label). For the format specification, refer to the following.
Page 358 TARGET_REF structure
Data type (TYPE)
The following shows data type that can be specified to the data name.
• Bit
• Word (signed)
• Double word (signed)
• Word (unsigned)
• Double word (unsigned)
• Single-precision real number
• Double-precision real number
When the device is specified to the data name, it is required to specify the data type as well. The data type also can be
specified by the specification of the NAME object. When both NAME and TYPE are specified, the specification of NAME takes
priority.
When the label is specified to the data name, the data type specification is ignored.
15 LOGGING
15.1 Data Logging/Real-Time Monitor