Mitsubishi Electric MELSEC iQ-R Series User Manual page 560

Motion module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Error
Error
code
(System/
(Hexad
axis/axes
ecimal)
group)
3491H
System
3492H
System
3493H
System
3494H
System
3495H
System
3496H
System
3497H
System
22 TROUBLESHOOTING
558
22.5 List of Error Codes
Error name
Error detail and cause
Data Source Target
The incorrect target modification
Modification Incorrect
is specified in ValueSource.
Calculation Profile
Memory capacity that exceeds
AddOn System Memory
the
Shortage
"System.PrConst.Addon_AddonL
ibraryName.RamSizeMax" was
used.
Calculation Profile
An error occurred in internal of
Addon Internal Error
calculation profile addon.
Axis Status Incorrect
MC_GroupEnable was executed
(When Axis Group is
when "AxisName.Md.AxisStatus"
Valid)
of configuration axis is other than
"StandStill" or "Disabled".
Axis Group Status
MC_GroupEnable was executed
Incorrect (When Axis
when
Group is Valid)
"AxesGroupName.Md.GroupStat
us" is other than "GroupStandby"
or "GroupDisabled".
Axis Group
MC_GroupEnable was executed
Configuration Axis Is in
for the axis group in which the
Use
"AxisName.Md.UseInGroup" of
configuration axis is TRUE (The
configuration axis is in use in
other axis group).
MCv_ChangeCycle
An error occurred during
Instruction Error
executing MCv_ChangeCycle
because of the following causes.
• "Cycle" is out of range (Detail
Code: 1)
• "ExecutionMode" is out of
range (Detail Code: 2)
• Changed current position is out
of range of software stroke limit
(Detail Code: 3)
• The executing axis status is
incorrect (Detail Code: 4)
• Other MCv_ChangeCycle was
executed in specified
instanceID(Detail Code: 8)
• "Options" is out of the range
(Detail Code: 9)
Detection
Operation at
timing (At
error
start/
occurrence
during
control
When
Not execute FB.
executing FB
At ready ON
The program stops.
At ready ON
The program stops.
When Axis
The axes group status
Group is Valid
does not turn
"GroupStandby"
When Axis
Not execute FB.
Group is Valid
When Axis
The axes group status
Group is Valid
does not turn
"GroupStandby"
At start
• The FB is not
During
executed.
operation
• The execution of FB is
interrupted.
Remedy
Set a normal target
modification.
Please check the
"System.PrConst.Addon
_AddonLibraryName.Ra
mSizeMax".
• Please install the
software again.
• Please write the
program again.
Execute
MC_GroupEnable after
setting "StandStill" or
"Disabled" in
"AxisName.Md.AxisStatu
s" of all configuration
axes.
Execute
MC_GroupEnable in the
status where
"AxesGroupName.Md.G
roupStatus" is
"GroupStandby" or
"GroupDisabled".
Disable the axis group in
use and execute
MC_GroupEnable.
• Set "Cycle" within the
range.
• Set "ExecutionMode"
within the range.
• Set the value of
changed current
position within
software stroke limit
range.
• Execute when axis
status is "Standstill".
• Set "Options" within
the range.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rd78g32Rd78g64Rd78ghvRd78g4Rd78ghwRd78g8 ... Show all

Table of Contents