Creating operation profile data

This section describes storage format and creating method of the operation profile data.
Storage format
The standard text (csv) can be used as the operation profile data in the motion system.
Storage format
Details
Standard text format
Stores the operation profile data as a standard text file (csv file) or
the compressed file (zip file).
Creating method when not using the engineering tool
When using the operation profile data in the control without using the engineering tool, execute the following procedures.
■When creating the operation profile data by a program
1.
Store data (read/write data structure for each type) corresponding to the operation profile data format that will be created
on the variables (labels and devices).
2.
Set the profile data type (standard/function specific) label as needed. (When storing created operation profile data in the
file, set the storage location in Location.)
3.
When executing the operation profile data write FB, the control ID can be obtained in the profile ID type (standard/
function specific) label.
4.
Execute the control FB by using the profile ID type (standard/function specific) label.
■When using the operation profile data created outside
1.
Store the operation profile data in an arbitrary place such as a user drive and a SD memory card.
2.
Set the storage location in Location of the profile data type (standard/function specific) label.
3.
When executing the open FB, the control ID can be obtained in the profile ID type (standard/function specific) label.
4.
Execute the control FB by using the profile ID type (standard/function specific) label.
Creating method when using the engineering tool
When using the engineering tool, it can be automatically opened to the motion system when the power turns ON and when
the PLC READY [Y0] turns ON by explicitly specifying the profile ID. (When the profile ID is not explicitly specified, it will not
be automatically opened.)
Automatically opened operation profile data can be used for control without executing the open FB.
Also, when the operation profile data is created in the engineering tool, the profile data type global label whose label name is
the operation profile data name is automatically added, and it can be used in the program. The set description (storage
location and ID) is reflected as the initial value of the profile data type.
Profile data type labels created by the engineering tool cannot be edited on the global label editor. Be sure to
create and edit it on the operation profile data create window.
13 OPERATION PROFILE FUNCTION
388
13.1 Operation Profile Data
Characteristics
The data created in the engineering tool can be stored in this
format.