Mitsubishi Electric MELSEC iQ-R Series User Manual page 478

Motion module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Trigger condition (TRIGGERCONDITION)
Item name
No.
Condition type
Data name
Condition
Data/constant
Data name (data name/
constant value)
Constant value (data name/
constant value)
Fixed-cycle
*1
Event code
*1 It is a unique setting item for the Motion module (Logger Module does not have this setting).
Data(DATA)
Item name
No.
Name
Data name
Data type
Input method
Axis type
*1 It is a unique setting item for the Motion module (Logger Module does not have this setting).
15 LOGGING
476
15.2 Data Logging Format
Data type
NO
number
TYPE
string
DATA1
number
DATAOPE
string
DATA2TYPE
string
DATA2
Number
DATA2CONST
string
CYCL
number
EVENTCODE
string
Data type
NO
number
NAME
string
DATA1
number
TYPE
string
INPUTMETHOD
number
AXISTYPE
string
Description
1 to 32 (Serial number is not required)
DATACOMP: Data condition (Comparison)
DATACHANGE: (Value change)
CYCLE: Fixed cycle
STARTMODULE: At module start
*1
EVENTHISTORY: Event history
LOGTRG: At trigger command execution
1 to 1024
EQUAL: =
NOTEQUAL: 
GREATERTHANEQUAL: 
GREATERTHAN: >
LESSTHANEQUAL: 
LESSTHAN: <
*1
RISINGEDGE: 
*1
FALLINGEDGE: 
DATA
CONST
1 to 1024
Constant value
Set 0/1 for bit data
1000000 to 86400000000[ns]
Set an unit of ms (floating point) on display
Event code (0xXXXXXXXX type, Settable in the range)
Description
1 to 1024 (Serial number is not required)
Label/device character string
1 to 1024
Available only at device specification.
(Ignores at label specification)
BIT: Bit (BIT)
SWORD: Word [signed]
SDWORD: Double word [signed]
UWORD: Word [unsigned]/Bit column (16 bits)
UDWORD: Double word [unsigned]/Bit column (32 bits)
FLOAT: Single-precision real number
DFLOAT: Double-precision real number
*1
SQWORD: Long word [signed]
UQWORD: Long word [unsigned]
<For data name restoration by logging setting tool>
0: Directly input (No restoration)
1: Input from label input assistant display (Restores label name)
No specification/value other than above: Directly input
<For data name restoration by logging setting tool>
• Available only at input method "1"
"SYSTEM": System
"AXIS_REAL": Real drive axis
"AXIS_VIRTUAL": Virtual drive axis
"AXIS_VIRTUAL_LINK": Virtual linked axis
"AXES_GROUP": Axes group
No specification/value other than above: Regard as directly input data
*1
*1