Stop Operation Of Output Axis - Mitsubishi Electric MELSEC iQ-F FX5 Series User Manual

Motion module/ simple motion module
Hide thumbs Also See for MELSEC iQ-F FX5 Series:
Table of Contents

Advertisement

Stop operation of output axis

If the following causes occur in stopping the output axis during synchronous control, synchronous control is completed after
stops processing for the output axis ("[Md.141] BUSY" is OFF, "[Md.26] Axis operation status" is standby).
Synchronous alignment must be executed for the output axis to restart the synchronous control. (Page 127 Output Axis
Module)
Stop cause
The target axis bit of "[Cd.380] Synchronous control start" is turned from ON to OFF.
Software stroke limit error occurrence
Emergency stop
Forced stop
*1
Stop group1 to 3
(Stop with hardware stroke limit or stop command)
*1 Refer to "Stop" in the following manual.
MELSEC iQ-F FX5 Motion Module/Simple Motion Module User's Manual (Application)
Immediate stop
The operation stops without decelerate. The Simple Motion module/Motion module immediately stops the command, but the
operation will coast for the droop pulses accumulated in the deviation counter of the servo amplifier.
[Md.407] Cam axis position
value per cycle
[Md.20] Command position
value
(Cam operation)
[Md.22] Speed command
[Cd.380] Synchronous control
start (Target axis bit)
[
Md.141] BUSY
(Target axis bit)
1 OUTLINE OF ADVANCED SYNCHRONOUS CONTROL
26
1.3 Operation Method of Synchronous Control
Stop process
Immediate stop
Deceleration stop
t
t
t
t
t
t
Immediate stop

Advertisement

Table of Contents
loading

Table of Contents