Cam data format (When the interpolation method specification is "2: Spline
interpolation")
The following shows a case for specifying setting value below.
Line
Colu
Item
No.
mn
No.
3
3
Interpolation
method
specification
■6th line: Number of sections
Specify the number of sections.
■7th line or later: Parameter
: Omission not possible
Line
Colu
Item
No.
mn
No.
7
1
End point
2
Stroke
8
1-2
Same as line No.7
(For the number of sections)
Setting value
2: Spline interpolation
Omis
Setting range (Initial value)
sion
Page 372 Operation Profile
Data
Setting
Description
format
Real
Page 372 Operation Profile Data
number
Real
number
13 OPERATION PROFILE FUNCTION
13.2 Operation Profile Data Format
13
Supported
file version
0x0103
0x0103