Mitsubishi Electric MELSEC iQ-R Series User Manual page 424

Motion module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

• (N-2)th line: Length per cycle
: Omission possible
Line
Colu
Item
No.
mn
No.
N-2
1
Length per cycle
2
Unit setting
3
Unit character string
4
Minimum value per
cycle
5
Maximum value per
cycle
6
Time per cycle
*3 The maximum value differs depending on the data format.
*4 Differs depending on the data format.
13 OPERATION PROFILE FUNCTION
422
13.2 Operation Profile Data Format
Omis
Setting range (Initial value)
sion
*3
0 or more
[Rules]
F: An arbitrary unit
Initial value: 0x0F
For settable units, refer to the
following.
Page 62 Technical Units
Initial value: ""
Page 62 Technical Units
*4
*4
*3
0 or more
Setting
Description
format
Real
Specifies the length per cycle. Specify
number
"0" for the data format that does not
require it.
Unsigned
Specifies the unit of the length per
integer
cycle.
Units that can be specified differ
depending on the profile data type.
Page 372 Operation Profile Data
Character
Specifies an arbitrary character string
string
when "an arbitrary unit" is set to the
unit setting.
Real
Specifies the minimum value of length
number
per cycle. Specify "0" for the data
format that does not require it.
Real
Specifies the maximum value of length
number
per cycle. Specify "0" for the data
format that does not require it.
Real
Specifies the time per cycle. Specify
number
"0" for the data format that does not
require it.
Supported
file version
0x0103
0x0103
0x0103
0x0103
0x0103
0x0103