Mitsubishi Electric MELSEC iQ-R Series User Manual page 205

Motion module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Name
Variable
name
Speed mode
VelocityMode
Buffer mode
BufferMode
Options
Options
*1 For a bit and the function description, refer to the following table.
Bit
Function description
0 to 2
Acceleration/deceleration method setting
0: mcAccDec (Acceleration/deceleration specification method)
1: mcFixedTime (Acceleration/deceleration time-fixed method)
For details, refer to the following.
Page 293 Acceleration/deceleration Processing Function
3
Position selection during buffer mode
FALSE: Set position
TRUE: Actual position
4 to 31
Empty (Set "0".)
■Output variables
Name
Variable name
Completion
Done
Executing
Busy
Controlling
Active
Abortion of execution
CommandAborted
Error
Error
Error code
ErrorID
Data type
Import
Setting range
MC_INTERPO
0 to 2
LATE_SPEED_
MODE
MC_BUFFER_
0 to 5
MODE
*1
DWORD(HEX)
Data type
BOOL
BOOL
BOOL
BOOL
BOOL
WORD (UINT)
Default
Description
value
0
Specifies the speed mode of interpolation control.
0: VectorSpeed (Vector speed)
1: LongAxisSpeed (Long axis speed)
2: ReferenceAxisSpeed (Reference axis speed)
0
Selects the buffer mode.
0: mcAborting (Aborting)
1: mcBuffered (Buffered)
2: mcBlendingLow (BlendingLow)
3: mcBlendingPrevious (BlendingPrevious)
4: mcBlendingNext (BlendingNext)
5: mcBlendingHigh (BlendingHigh)
For details, refer to the following.
Page 107 Multiple Start (Buffer Mode)
00000000H
Sets a function option with bit specification.
Default
Description
value
FALSE
Indicates that the control is completed.
When Execute is TRUE at the operation
completion, TRUE remains until Execute turns
FALSE.
When Execute is FALSE at the operation
completion, it becomes TRUE only for one cycle.
FALSE
Indicates that the FB is in execution.
FALSE
Indicates that the axis is being controlled. When
multiple FBs are executed for the same axes
group, Active of only one FB turns TRUE.
FALSE
Indicates that execution of FB has been aborted
due to error or multiple start.
FALSE
Indicates that an error has occurred.
0000H
The generated error code is returned.
For details, refer to the following.
Page 534 List of Error Codes
6 AXIS CONTROL FUNCTION
6.4 Multiple Axes Positioning Control
6
203

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rd78g32Rd78g64Rd78ghvRd78g4Rd78ghwRd78g8 ... Show all

Table of Contents