22 TROUBLESHOOTING
546
22.5 List of Error Codes
Error name
Error detail and cause
Target of STOP Signal
• The type that can not be used
Incorrect
was specified in the
"AxisName.Pr.StopSignal.Sour
ce.Target".
• The target modification is not
set in the type where the target
modification of
"AxisName.Pr.StopSignal.Sour
ce.Target" is necessary.
Target of Forced Stop
• The type that can not be used
Signal Incorrect
was specified in the
"AxisName.Pr.ForcedStop.Sou
rce.Target".
• The target modification is not
set in the type where the target
modification of
"AxisName.Pr.ForcedStop.Sou
rce.Target" is necessary.
Target of All Axes
• The type that can not be used
Forced Stop Signal
was specified in the
Incorrect
"System.Pr.ForcedStop.Source
.Target".
• The target modification is not
set in the type where the target
modification of
"System.Pr.ForcedStop.Source
.Target" is necessary.
Variable Manager
Forced stop has failed to acquire
Acquisition Failure
variable manager.
External Signal
FLS/RLS/STOP/Each axis/all
Selection AddOn
axes forced stop signal is failed to
Acquisition Failure
acquire the external signal
selection addon.
FLS Signal Fixed Scan
Failed to register the
Refresh Registration
"AxisName.PrConst.HwStrokeLi
Failure
mit_FlsSignal" fixed scan refresh.
RLS Signal Fixed Scan
Failed to register the
Refresh Registration
"AxisName.PrConst.HwStrokeLi
Failure
mit_RlsSignal" fixed scan refresh.
STOP Signal Fixed
Failed to register the
Scan Refresh
"AxisName.Pr.StopSignal" fixed
Registration Failure
scan refresh.
Forced Stop Signal
Failed to register the
Fixed Scan Refresh
"AxisName.Pr.ForcedStop" fixed
Registration Failure
scan refresh.
Detection
Operation at
timing (At
error
start/
occurrence
during
control
At ready ON
The signal is detected
continuously.
At ready ON
The signal is detected
continuously.
At ready ON
The signal is detected
continuously.
At ready ON
The all axes forced stop
signal is not detected
continuously. (The
function is invalid.)
At ready ON
The signal is detected
continuously.
At ready ON
The signal is detected
continuously.
At ready ON
The signal is detected
continuously.
At ready ON
The signal is detected
continuously.
At ready ON
The signal is detected
continuously.
Remedy
Set the valid string in the
"AxisName.Pr.StopSigna
l.Source.Target".
Set the valid string in the
"AxisName.Pr.ForcedSto
p.Source.Target".
Set the valid string in the
"System.Pr.ForcedStop.
Source.Target".
Install variable manager
and enable it.
Install external signal
addon and enable it.
Increase the memory
capacity that set in
system. Or, delete
unnecessary axis and
reduce memory size of
axis data to memory
capacity.
Increase the memory
capacity that set in
system. Or, delete
unnecessary axis and
reduce memory size of
axis data to memory
capacity.
Increase the memory
capacity that set in
system. Or, delete
unnecessary axis and
reduce memory size of
axis data to memory
capacity.
Increase the memory
capacity that set in
system. Or, delete
unnecessary axis and
reduce memory size of
axis data to memory
capacity.