Error
Error
Error name
code
(System/
(Hexad
axis/axes
ecimal)
group)
3498H
System
MCv_ChangeCycleTrig
gered Instruction Error
3499H
System
AddOn Memory
Shortage
349AH
System
Memory Shortage
349BH
System
Motion Command
Execution at STOP
34F8H
System
Device/Label
Specification Incorrect
34F9H
System
FB/FUN Callee
Incorrect
34FAH
System
Label Temporary Area
Incorrect
34FBH
System
DI Instruction Nesting
Number Error
34FCH
System
FB/FUN Call Nesting
Number Error
34FDH
System
Pointer execution error
Error detail and cause
Detection
timing (At
start/
during
control
An error occurred during
At start
executing
During
MCv_ChangeCycleTriggered
operation
because of the following causes.
• "Cycle" is out of range (Detail
Code: 1)
• "ExecutionMode" is out of
range (Detail Code: 2)
• Changed current position is out
of range of software stroke limit
(Detail Code: 3)
• The executing axis status is
incorrect (Detail Code: 4)
• "TriggerInput" is incorrect
(Detail Code: 5, 6)
• AddOn SignalIO has not been
enabled. (Detail Code: 7)
• Other
MCv_ChangeCycleTriggered
was executed in specified
instanceID(Detail Code: 8)
• "Options" is out of the range
(Detail Code: 9)
The related addon memory is
At start up
insufficient.
The memory capacity in which
When
MCFB instance is created is
executing
insufficient.
dedicated
instruction
Motion Command Execution was
When
executed when it is in STOP
executing
status.
dedicated
instruction
The device or label that cannot
When
be used in the instruction was
executing
specified.
instruction
The function block (FB) or
When
function (FUN) specified in the
executing
program does not exist.
instruction
The label temporary area was
When
used incorrectly.
executing
instruction
The number of nesting levels in
When
the DI instruction exceeded its
executing
limit (16).
instruction
The number of nesting levels in
When
the function block (FB) or function
executing
(FUN) exceeded its limit (32).
instruction
• The pointer specified in The
When
instruction does not exist.
executing
• The usable range was
instruction
exceeded when the array
element was specified
dynamically.
Operation at
Remedy
error
occurrence
• The FB is not
• Set "Cycle" within the
executed.
range.
• The execution of FB is
• Set "ExecutionMode"
interrupted.
within the range.
• Set the value of
changed current
position within
software stroke limit
range.
• Execute when axis
status is "Standstill".
• Check the setting of
"TriggerInput".
• Please enable addon
SignalIO.
• Set "Options" within
the range.
The FB is not executed.
Please increase
System.PrConst.Addon_
AddonLibraryName.Ram
SizeMax.
Dedicated instruction is
Check setting data.
completed with the error.
Dedicated instruction is
Set module to RUN
completed with the error.
status.
Program stops/keeps
Please check and
Follow the setting below.
correct error occurrence
Operation setting at
points.
error: Invalid device/
label/buffer memory
specification
The program stops.
• Please check the error
occurrence points and
correct it.
• Please write the
program again.
The program stops.
Please write the
program again.
The program stops.
Please change the
number of nesting levels
(16 or less).
The program stops.
Please change the
number of nesting levels
(32 or less).
The program stops.
• Please check the error
occurrence points and
correct it.
• Please write the
program again.