Mitsubishi Electric MELSEC iQ-R Series User Manual page 423

Motion module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

The common items as operation profile data are shown below.
: Omission possible, : Omission not possible
Line
Colu
Item
No.
mn
No.
2
1
Profile ID
2
Periodic
3
Input absolute
coordinate
4
Output absolute
coordinate
3
1
Operation profile
data format
2
Profile data type
3
Interpolation
method
specification
4
1
Resolution and
number of
coordinates
5
1
Start point
2
Initial stroke amount
3
Initial velocity
4
Initial accrlrration
5
Options
6
1
Number of sections
*1 Differs depending on the data format.
*2 Depends on the operation profile data format.
Omis
Setting range (Initial value)
sion
Page 372 Operation Profile
Data
Initial value: 0 (= automatic apply)
Page 372 Operation Profile
Data
Page 372 Operation Profile
Data
Page 372 Operation Profile
Data
99: Cam data format
0: General profile data
1: Cam data
6: Digital output data format
Initial value: 0
0: Linear interpolation
1: Specifying for each section
2: Spline interpolation
Initial value: 0
Page 372 Operation Profile
Data
Initial value: 0
*1
99: Valid for the cam data format
(specified for each section, spline
interpolation)
Initial value: 0
*1
99: Valid for the cam data format
(specified for each section, spline
interpolation)
Initial value: 0
*1
99: Valid for the cam data format
(specified for each section)
Initial value: 0
*1
99: Valid for the cam data format
(specified for each section)
Initial value: 0
*2
Initial value: 0
*2
Initial value: 0
Setting
Description
format
Unsigned
Specifies Profile ID. (Use only when
integer
carrying out automatic open when the
power turns ON.)
Integer
Specifies periodic.
Integer
Specifies input absolute coordinate.
Integer
Specifies output absolute coordinate.
Integer
Specifies operation profile data format.
Integer
Specifies the profile data type.
Page 372 Operation Profile Data
Integer
Specifies the interpolation method
between data.
Unsigned
Sets the resolution or the number of
integer
coordinates.
Real
Specifies the start point.
number
Real
Specifies the initial stroke amount.
number
Real
Specifies the initial velocity
number
Real
Specifies the initial accrlrration
number
Unsigned
Defines for each operation profile data
integer
format.
Unsigned
Specifies the number of sections for
integer
the data format that requires it. Specify
"0" for the data format that does not
require it.
13 OPERATION PROFILE FUNCTION
13.2 Operation Profile Data Format
Supported
file version
0x0103
0x0103
0x0103
0x0103
0x0103
0x0103
13
0x0103
0x0103
0x0103
0x0103
0x0103
0x0103
0x0103
0x0103
421