Mitsubishi Electric MELSEC iQ-R Series User Manual page 545

Motion module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Error
Error
Error name
code
(System/
(Hexad
axis/axes
ecimal)
group)
1A9AH
Axis
Absolute Position
Management Setting
Mismatch
1AA3H
Axis
Out of Ring Counter
Range
1AA4H
Axis
Driver Unit Change
Magnification Upper
Over
1AA5H
Axis
Driver Unit Change
Numerator/
Denominator Change
Timing Incorrect
1AA7H
Axis
AddOn Acquisition
Failure
1AA8H
Axis/Axes
Necessary Slave Object
group
Unset
1AA9H
Axis/Axes
Out of Acceleration/
group
Deceleration Method
Range
1AAAH
Axis
ABS Reference Point
Read Error
1AABH
Axes group
Reference Axis
Movement Amount 0
1AACH
Axis
Out of Torque Lamp
Function Selection
Range
Error detail and cause
Detection
timing (At
start/
during
control
The ENCODER_ABS_STATUS
When
object setting in connection
restoring
devices is not match.
current
position
• The setting of ring counter
At power ON
upper limit value and lower limit
value exceeds the positioning
range.
• Ring counter lower limit value >
Ring counter upper limit value.
• When 0 < |Ring counter upper
limit value - Ring counter lower
limit value| < 2.0
• The setting value exceeded the
positioning range.
The magnification that exceeded
At ready ON
upper limit in the driver unit
conversion numerator/
denominator is set.
The driver unit conversion
At ready ON
numerator/denominator setting
was changed when follow-up
operation can not be executed.
Failed to acquire the external
At power ON
signal selection addon when
have 'counter disable signal'
setting.
Necessary slave object in control
At start
command execution is not set to
At multipul
axis (occasion configuration axis
start
of axis group).
The value is out of range for
At start
acceleration/deceleration method
At multipul
of "Options".
start
Failed to get the data from drive
During
module normally at homing.
operation
The movement amount of the
At start
reference axis is "0" in the linear
At multipul
interpolation for reference axis
start
specification.
The value is out of range for
At start
torque lamp function selection of
"Options".
Operation at
Remedy
error
occurrence
Current position is not
Please correct the axis
restored.
and absolute position
management setting of
connection devices.
Generating axis fails.
• Set the ring counter
upper limit value and
lower limit value within
the positioning range.
• Set the values so that
they meet the
following condition:
Ring counter lower
limit value < Ring
counter upper limit
value.
• Set the values so that
they meet the
following condition:
2.0 < |Ring counter
upper limit value -
Ring counter lower
limit value|.
The driver unit
Set the calculation result
conversion numerator/
of driver unit conversion
denominator is not
numerator/denominator
changed.
that does not exceed
800000000.
The driver unit
READY ON when follow-
conversion numerator/
up is possible.
denominator is not
Both of the following
changed.
points are satisfied.
• +H4 is Disabled.
• "AxisName.Md.Followu
pDisableStatus" is
FALSE.
Generating axis fails.
Install external signal
addon and enable it.
• [At start] Not start.
• Please set necessary
• [At multipul start]
object in control
Stops the operation.
command.
• Please use single axis
synchronization for
virtual link axis.
• [At start] Not start.
Set the acceleration/
• [At multipul start]
deceleration method
Stops the operation.
according to the
executed control
command.
Homing is not completed
Execute homing again.
normally.
• [At start] Not start.
Set the axis of which the
• [At multipul start]
movement amount is not
Stops the operation.
0 to a reference axis.
• [At start] Not start.
Set torque lamp function
• [At multipul start]
selection of "Options"
Stops the operation.
within the range.
22 TROUBLESHOOTING
22.5 List of Error Codes
22
543

Hide quick links:

Advertisement

Table of Contents