Mitsubishi Electric MELSEC iQ-R Series User Manual page 538

Motion module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Error
Error
code
(System/
(Hexad
axis/axes
ecimal)
group)
1A1FH
Axis
1A20H
Axis
1A22H
Axis
1A26H
Axis
1A27H
Axes group
1A28H
Axis
1A29H
Axis
1A2DH
Axis
1A2EH
Axis
1A2F
Axis
1A30H
Axis
1A32H
Axis/Axes
group
1A34H
Axis/Axes
group
1A35H
Axis
22 TROUBLESHOOTING
536
22.5 List of Error Codes
Error name
Error detail and cause
Out of Torque Positive
The value is out of range for
Direction Ramp Range
"TorquePositiveRamp".
Out of Torque Negative
The value is out of range for
Direction Ramp Range
"TorqueNegativeRamp".
Start during homing
The positioning was started when
Incomplete
homing request flag is on.
Axis Status Incorrect
The axis is started in the status
Start
except when
"AxisName.Md.AxisStatus" is
StandStill.
Axis Group Status
The axis group is started in the
Incorrect Start
status except when
"AxesGroupName.Md.AxesGrou
pStatus " is Standby.
Out of Phase
The value is out of range for
Compensation Advance
"Time".
Time Range
Out of Phase
The value is out of range for
Compensation Time
"TimeConstant".
Constant Range
FLS Signal Detection
The signal input from FLS signal
(at Start)
at start was detected.
RLS Signal Detection
The signal input from RLS signal
(at Start)
at start was detected.
FLS Signal Detection
The signal input from FLS signal
(Controlling)
during controlling was detected.
RLS Signal Detection
The signal input from RLS signal
(Controlling)
during controlling was detected.
Out of Movement
The value is out of range for
Amount Range
"Distance".
Out of Gear
The value is out of range for
Denominator Range
"RatioDenominator".
Out of Time Constant
The value is out of range for
Range
"TimeConstant".
Detection
Operation at
timing (At
error
start/
occurrence
during
control
At start
Not start.
At start
Not start.
At start
Not start.
At start
Not start.
At start
Not start.
At start
Not start.
At start
Not start.
At start
Not start.
At start
Not start.
During
Stops.
control
During
Stops.
control
At start
Not start.
At start
Not start.
At start
Not start.
Remedy
Set
"TorquePositiveRamp"
within the range.
Set
"TorqueNegativeRamp"
within the range.
Start the operation after
executing homing.
Start the axis group in
the status when
"AxisName.Md.AxisStatu
s" is StandStill.
Start the axis group
operation in the status
where
"AxesGroupName.Md.A
xesGroupStatus" is
Standby.
Set a value within the
range for "Time".
Set a value within the
range for
"TimeConstant".
Set "ONLY_INSIDE" or
"DISABLE" to
"AxisName.Cd.HwStrok
eLimit_Override" and
move to the controllable
range.
Set "ONLY_INSIDE" or
"DISABLE" to
"AxisName.Cd.HwStrok
eLimit_Override" and
move to the controllable
range.
Set "ONLY_INSIDE" or
"DISABLE" to
"AxisName.Cd.HwStrok
eLimit_Override" and
move to the controllable
range.
Set "ONLY_INSIDE" or
"DISABLE" to
"AxisName.Cd.HwStrok
eLimit_Override" and
move to the controllable
range.
Set a value within the
range for "Distance".
Set a value within the
range for
"RatioDenominator".
Set a value within the
range for
"TimeConstant".

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rd78g32Rd78g64Rd78ghvRd78g4Rd78ghwRd78g8 ... Show all

Table of Contents