Mitsubishi Electric MELSEC iQ-R Series User Manual page 557

Motion module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Error
Error
Error name
code
(System/
(Hexad
axis/axes
ecimal)
group)
3453H
System
Calculation Profile
Control Unsupported
3454H
System
Input Data Data Type
Incorrect
3455H
System
Input Data Data Name
Specification Method
Incorrect
3456H
System
Input Data Type
Incorrect
3457H
System
Output Data Data Type
Incorrect
3458H
System
Output Data Data Name
Specification Method
Incorrect
3459H
System
Output Data Type
Incorrect
345AH
System
Out of Output Offset
Range
345BH
System
Out of Input Offset
Range
345CH
System
Out of Output
Coefficient Range
345DH
System
Out of Input Coefficient
Range
345EH
System
Calculation Profile
Read/Write
Unsupported
345FH
System
Out of Read Target/
Write Target Range
3460H
System
Read/Write Data Data
Type Incorrect
3461H
System
Read/Write Data Data
Name Specification
Method Incorrect
3462H
System
Read/Write Data Type
Incorrect
3463H
System
Read/Write Data Target
Modification Incorrect
3464H
System
Number of Read/Write
Data Mismatch
Error detail and cause
Detection
timing (At
start/
during
control
Control FB was executed for the
At start
unsupported calculation profile.
The incorrect data type is set in
During
Inputs.Target.
operation
The incorrect data name
During
specification method is set in
operation
Inputs.Target.
The incorrect type is set in
During
Inputs.Target.
operation
The incorrect data type is set in
During
Output.Target.
operation
The incorrect data name
During
specification method is set in
operation
Output.Target.
The incorrect type is set in
During
Output.Target.
operation
The value is out of range for
At start
OutputOffset.
During
operation
The value is out of range for
At start
InputsOffset.
During
operation
The value is out of range for
At start
OutputScaling.
During
operation
The value is out of range for
At start
InputsScaling.
During
operation
The calculation profile which
During
does not support calculation
operation
profile read/write is set.
The value is out of range for
During
Target.
operation
The incorrect data type is set in
During
Data1 or Data2.
operation
The incorrect data name
During
specification method is set in
operation
Data1 or Data2.
The incorrect type is set in Data1
During
or Data2.
operation
The incorrect target modification
During
is set in Data1 or Data2.
operation
Points do not match the number
During
of elements of read/write
operation
structured data type.
Operation at
Remedy
error
occurrence
The FB is not executed.
Open the calculation
profile which supports
the calculation profile
control FB in the open
area.
The execution of FB is
Set a normal data type in
interrupted.
Inputs.Target.
The execution of FB is
Set a normal data name
interrupted.
specification method in
Inputs.Target.
The execution of FB is
Set a normal type in
interrupted.
Inputs.Target.
The execution of FB is
Set a normal data type in
interrupted.
Output.Target.
The execution of FB is
Set a normal data name
interrupted.
specification method in
Output.Target.
The execution of FB is
Set a normal type in
interrupted.
Output.Target.
• [At start] The FB is not
Set OutputOffset within
executed.
the range.
• [During operation]
Operates with
previous setting value.
• [At start] The FB is not
Set a value within the
executed.
range for InputsOffset.
• [During operation]
Operates with
previous setting value.
• [At start]The FB is not
Set a value within the
executed.
range for OutputScaling.
• [During operation]
Operates with
previous setting value.
• [At start]The FB is not
Set a value within the
executed.
range for InputsScaling.
• [During operation]
Operates with
previous setting value.
The execution of FB is
Set the calculation
interrupted.
profile which supports
read/write.
The execution of FB is
Set a value within the
interrupted.
range for Target.
The execution of FB is
Set a normal data type in
interrupted.
Data1 and Data2.
The execution of FB is
Set a normal data name
interrupted.
specification method in
Data1 and Data2.
The execution of FB is
Set a normal type in
interrupted.
Data1 and Data2.
The execution of FB is
Specify a normal target
interrupted.
modification in Data1
and Data2.
The execution of FB is
Set Points to match with
interrupted.
the number of elements
of read/write structured
data type.
22 TROUBLESHOOTING
22.5 List of Error Codes
22
555