Axes group error reset

Reset the error/warning of the axes group by AxesGroupName.Cd.ErrorReset.
Reset also each axis error which belongs to the axes group in addition to the error/warning of the axes group.
Control details
■AxesGroupName.Cd.ErrorReset
• Reset is executed at the rising edge detection of AxesGroupName.Cd.ErrorReset.
• When the reset is completed, AxesGroupName.Cd.ErrorReset becomes FALSE.
• When the error reset of the configuration axis is not completed, the error reset of the axes group is not completed.
• If the error reset is not succeeded, AxesGroupName.Cd.ErrorReset remains TRUE.
• The error reset can be canceled by changing AxesGroupName.Cd.ErrorReset to FALSE.
AxesGroupName.Cd.ErrorReset
AxesGroupName.Md.Error
AxisGroupName.Md.ErrorID
AxisGroupName.Md.AxisStatus
AxisName1.Md.Error
AxisName1.Md.ErrorID
AxisName1.Md.AxisStatus
AxisName2.Md.Error
AxisName2.Md.ErrorID
AxisName2.Md.AxisStatus
Error code
1: GroupErrorStop
Error code
1: ErrorStop
0: Disabled or 4: StandStill
Error code
1: ErrorStop
0: Disabled or 4: StandStill
0
4: GroupStandby
0
0