Mitsubishi Electric MELSEC iQ-R Series User Manual page 549

Motion module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Error
Error
Error name
code
(System/
(Hexad
axis/axes
ecimal)
group)
1AD0H
Axis (All
All Axes Forced Stop
axes)
Signal Fixed Scan
Refresh Registration
Failure
1AD1H
Axis
Out of Signal Logical
Setting of FLS Signal
Range
1AD2H
Axis
Out of Signal Logical
Setting of RLS Signal
Range
1AD3H
Axis
Out of Signal logical
setting of STOP signal
range
1AD4H
Axis
Out of Signal Logical
Setting of Forced Stop
Signal Range
1AD5H
Axis (All
Out of Signal Logical
axes)
Setting of All Axes
Forced Stop Signal
Range
1AD8H
Axis
Out of Master Axis No.
Range
1AD9H
Axis
Out of Slave Axis No.
Range
1ADAH
Axis
Out of BufferMode
Range
1ADBH
System
Command Filter AddOn
System Memory
Shortage
1ADCH
System
AddOn System Memory
Shortage
1ADEH
Axes group
Out of Liner Movement
Amount Range
Error detail and cause
Detection
timing (At
start/
during
control
Failed to register the
At ready ON
"System.Pr.ForcedStop" fixed
cycle refresh.
The value is out of range for
At ready ON
"AxisName.Pr.Const.HwStrokeLi
mit_FlsSignal.Detection".
The value is out of range for
At ready ON
"AxisName.Pr.Const.HwStrokeLi
mit_RlsSignal.Detection".
The value is out of range for
At ready ON
"AxisName.Pr.StopSignal.Detecti
on".
The value is out of range for
At ready ON
"AxisName.Pr.ForcedStop.Detect
ion".
The value is out of range for
At ready ON
"System.Pr.ForcedStop.Detection
".
The value is out of range for
At start
Master.AxisNo.
When
executing FB
The value is out of range for
At start
Slave.AxisNo.
When
executing FB
The value is out of range for
At start
BufferMode.
When
executing FB
Memory capacity that exceeds
At start
the
At multipul
"System.PrConst.Addon_AddonL
star
ibraryName.RamSizeMax" was
used.
In AddOn related to operation,
At start
Memory capacity that exceeds
At multipul
the
star
"System.PrConst.Addon_AddonL
ibraryName.RamSizeMax" was
used.
The interpolation axis exists in
At start
which movement amount
At multipul
exceeds '4,294,967,296.0 ( =
star
32
2
)' in the linear interpolation for
composite speed specification.
Operation at
Remedy
error
occurrence
The signal is detected
Increase the memory
continuously.
capacity that set in
system. Or, delete
unnecessary axis and
reduce memory size of
axis data to memory
capacity.
The signal is detected
Set a value within the
continuously.
range for
"AxisName.Pr.Const.Hw
StrokeLimit_FlsSignal.D
etection".
The signal is detected
Set a value within the
continuously.
range for
"AxisName.Pr.Const.Hw
StrokeLimit_RlsSignal.D
etection".
The signal is detected
Set a value within the
continuously.
range for
"AxisName.Pr.StopSigna
l.Detection".
The signal is detected
Set a value within the
continuously.
range for
"AxisName.Pr.ForcedSto
p.Detection".
The signal is detected
Set a value within the
continuously.
range for
"System.Pr.ForcedStop.
Detection".
The FB is not executed.
• Set a value within the
range for
Master.AxisNo.
• Set the axis No. in
which instance is
created.
The FB is not executed.
• Set a value within the
range for
Slave.AxisNo.
• Set the axis No. in
which instance is
created.
The FB is not executed.
Set a value within the
range for BufferMode.
Not start.
Please check the
"System.PrConst.Addon
_AddonLibraryName.Ra
mSizeMax".
Not start.
Please check the
"System.PrConst.Addon
_AddonLibraryName.Ra
mSizeMax".
• [At start] Not start.
Set the "Position" or
• [At multipul star] Stops
"Distance" value so that
the operation.
the movement amount of
each interpolation axis
does not exceed
'4,294,967,296.0 ( =
32
2
)'.
22 TROUBLESHOOTING
22.5 List of Error Codes
22
547

Hide quick links: