Error
Error
Error name
code
(System/
(Hexad
axis/axes
ecimal)
group)
1C85H
System
Event History File
Incorrect
1C86H
System
Out of Cycle Over Error
Selection Range
1C87H
System
Label Incorrect
1C88H
System
Label Memory Shortage
1D80H
System
Out of Parameter
Range (Axis)
1D81H
System
Out of Parameter
Range (Axis Group)
1D82H
System
Out of Parameter
Range (System)
1D83H
System
Parameter Write-
protected
Error detail and cause
Detection
timing (At
start/
during
control
An error was detected in the
At updating
event history file.
the event
history file.
The value is out of range for
At power ON
"Cycle Over Error Selection".
Failed to import the label
At power ON
definition.
Label which exceeds the label
At power ON
capacity has been defined.
At ready ON
Parameter is out of the range.
When
executing FB
At power ON
At ready ON
Parameter is out of the range.
When
executing FB
At power ON
At ready ON
Parameter is out of the range.
When
executing FB
At power ON
At ready ON
Wrote in the parameter which can
When
only read.
executing FB
Operation at
Remedy
error
occurrence
Updating the event
• Delete unnecessary
history file stops.
files to secure the free
capacity.
• Format Target Drive.
• Delete event history
file.
• Please check the
memory capacity of
Addon
MotionEventHist.
Operates in default cycle
Please set the followings
over error type.
within the range.
• "System.PrConst.Syst
emBaseCycle.CycleO
verErrorType"
• "System.PrConst.Oper
ationCycle[1].CycleOv
erErrorType"
• "System.PrConst.Buffe
rmemoryRefreshCycle
.CycleOverErrorType"
Interrupts the process to
Please write label
import the labels.
setting.
Interrupts the process to
• Please change the
import the labels.
System.Md.LabelMem
oryFreeSize to a
larger value.
• Please check the label
usage.
• [When executing FB]
Change the specified
The error of FB turns
value of detailed
ON and the operation
information parameter
is not executed.
within range.
• [At power ON]
Generating axis fails.
• [At ready ON] The
READY signal (OX)
does not turn ON.
• [At FB] The error on
Change the specified
FB turns ON and the
value of detailed
operation is not
information parameter
executed.
within range.
• [At power ON]
Generating axes
group fails.
• [At ready ON] The
READY signal (OX)
does not turn ON.
• [At FB] The error of FB
Change the specified
turns ON and the
value of detailed
operation is not
information parameter
executed.
within range.
• [At power ON/At ready
ON] The READY
signal (OX) does not
turn ON.
Change to the parameter
The error of FB turns ON
and the operation is not
that can be written.
executed.