■System settings

Displayed items
• System settings
Item
[Variable/Structure name]
System
Addon  parameter
*1
parameter
[]
constant
Buffer memory refresh
cycle setting
[System.PrConst.Buffer
memoryRefreshCycle]
CPU event history excluded event
[System.PrConst.EventHistoryCpu_Exclude]
Motion event history capacity
[System.PrConst.EventHistoryMotion_Capacity]
Motion event history excluded event
[System.PrConst.EventHistoryMotion_Exclude]
Motion event history path
[System.PrConst.EventHistoryMotion_Path]
Excluded warning
[System.PrConst.ExcludeWarning]
For manufacturer setting
File transfer access control (file in latch drive)
[System.PrConst.FileTransfer_AcFile_lch]
File transfer access control (file in RAM drive)
[System.PrConst.FileTransfer_AcFile_ram]
File transfer access control (file in user drive)
[System.PrConst.FileTransfer_AcFile_rom]
File transfer access control (file in SD memory card)
[System.PrConst.FileTransfer_AcFile_sdc]
File transfer access control (file in system drive)
[System.PrConst.FileTransfer_AcFile_sys]
File transfer access control (latch drive image)
[System.PrConst.FileTransfer_AcImage_lch]
1.
2.
Maximum RAM size
[ADDON_PARAM.RamSizeMax]
Maximum backup RAM size
[ADDON_PARAM.BackupRamSizeMax]
Cycle setting
[CYCLE_PARAM.Cycle]
Number of cycle over warning detections
[CYCLE_PARAM.NumOfCycleOverWngDetectTime
s]
Number of cycle over error detections
[CYCLE_PARAM.NumOfCycleOverErrDetectTimes]
Cycle over error selection
[CYCLE_PARAM.CycleOverErrorType]
From the [Navigation window], select [System Setting] to
display the parameter editor.
Set the parameters for the system settings.
When the setting of parameters for the system settings is
complete, click the [Apply] button.
Setting range
0: Automatic setting
0 to 65535
0 to 65535
0: None
1: Warning
2: Minor error
3: Moderate error
4: Major error
1 to 2048[kB]
Read protected/write protected,
read permitted/write protected,
read permitted/write permitted
Appendix 2 Motion Module Programs
Initial value
*1
*1
0
1
A
5
3: Moderate error
0x700-0x7ff
128[kB]
No setting
No setting
No setting
0000
Read permitted/
write permitted
Read permitted/
write permitted
Read permitted/
write protected
Read permitted/
write permitted
Read permitted/
write protected
Read permitted/
write permitted
APPX