Oxygen Sensor Check - Mitsubishi MOTORS Space Runner 1999 Workshop Manual Supplement

Hide thumbs Also See for Space Runner 1999:
Table of Contents

Advertisement

13D-88
Equipment
side connector
Red
Blue
MD998464
Jumper
wire
White
Red
Black
MD998464
MPI -
On-vehicle Service

OXYGEN SENSOR CHECK

<Oxygen sensor (front)>
Oxygen sensor
1. Disconnect the oxygen sensor connector and connect
2. Make sure that there is continuity (11 - 18 W at 20_C)
Oxygen
sensor
3. If there is no continuity, replace the oxygen sensor.
equip-
4. Warm up the engine until engine coolant is 80_C or higher.
ment side
connector
5. Use a jumper wire to connect terminal 2 (red clip) of
Blue
6. Connect a digital voltage meter between terminal 1 (black
7. While repeatedly racing the engine, measure the oxygen
8. If the sensor is defective, replace the oxygen sensor.
the special tool (test harness) to the connector on the
oxygen sensor side.
between terminal 2 (red clip of special tool) and terminal
4 (blue clip of special tool) on the oxygen sensor connector.
the oxygen sensor connector to the battery (+) terminal
and terminal 4 (blue clip) to the battery ( - ) terminal.
Caution
Be very careful when connecting the jumper wire;
incorrect connection can damage the oxygen sensor.
clip) and terminal 3 (white clip).
sensor output voltage.
Standard value:
Engine
Oxygen sensor
output voltage
When
0.6 - 1.0 V
racing the
engine
NOTE
For removal and installation of the oxygen sensor, refer
to GROUP 15 - Exhaust Pipe and Main Muffler.
Remarks
If you make the air/fuel ratio
rich by racing the engine
repeatedly, a normal oxy-
gen sensor will output a
voltage of 0.6 - 1.0 V.