BODY –
Door
3. Move the window lock switch to the normal position, and
then measure the voltage at terminal (14) under the
measurement conditions given below.
Measurement condition
Apply battery voltage to terminal 9
Remove voltage from terminal (9).
Earth terminal (11) within 30 sec-
onds after voltage is removed from
terminal (9).
Disconnect earth from terminal (11)
within 30 seconds after earthing it.
POWER WINDOW SUB-SWITCH CONTINUITY CHECK
Terminal No.
Switch position
UP
AUTO UP
OFF
DOWN
AUTO DOWN
Voltage
Battery voltage
Battery voltage (for 30
seconds after voltage is
removed)
Battery voltate (for 30
seconds after earthing)
0 V
0V
1
2
3
4
42-41
0 V
6
7
8