5.15 Resetting the Absolute Encoder

5.15.3 Applicable Tools

5.15.3 Applicable Tools

The following table lists the tools that you can use to reset the absolute encoder and the appli-
cable tool functions.
Digital Operator
SigmaWin+
Serial command com-
munications

5.15.4 Operating Procedure

Use the following procedure to reset the absolute encoder.
1.
Confirm that the servo is OFF.
2.
Click the
3.
Select Absolute Encoder Reset in the Menu Dialog Box.
The Absolute Encoder Reset Dialog Box will be displayed.
4.
Click the Continue Button.
Click the Cancel Button to cancel resetting the absolute encoder. The Main Window will return.
5.
Click the Execute setting Button.
The current alarm code and name will be displayed in the Alarm name Box.
5-48
Tool
Fn008
Setup - Absolute Encoder Reset
ABSPGRES utility command
Servo Drive Button in the workspace of the Main Window of the SigmaWin+.
Function
Reference
Σ-7-Series Digital Operator Operating
Manual (Manual No.: SIEP S800001 33)
5.15.4 Operating Procedure on page 5-48
Monitor and Utility Function Commands
on page 14-32