Overheat Protection Selection - YASKAWA E-7S SERVOPACK SGD7S Product Manual

E-7-series ac servo drive e-7s servopack command option attachable type with indexer module
Table of Contents

Advertisement

6.12.2

Overheat Protection Selection

The overheat protection function is selected with Pn61A = n.
Selections).
Parameter

n.
(default setting)

n.
Pn61A

n.

n.
*
The SGLFW2 is the only Yaskawa Linear Servomotor that supports this function.
Using Overheat Protection in the Yaskawa Linear Servomotor
To use the overheat protection in the Yaskawa Linear Servomotor (SGLFW2), set Pn61A to

n.
1.
An A.93B warning (Overheat Warning) will be detected if the overheat protection input (TH) sig-
nal from the Yaskawa SGLFW2 Linear Servomotor exceeds the warning temperature.
An A.862 alarm (Overheat Alarm) will be detected if the overheat protection input (TH) signal
from the Yaskawa SGLFW2 Linear Servomotor exceeds the alarm temperature.
• If the overheat protection input signal line is disconnected or short-circuited, an A.862 alarm
will occur.
• If you set Pn61A to n.1 (Use overheat protection in the Yaskawa Linear Servomotor), the
Important
parameters in the Servomotor are enabled and the following parameters are disabled.
• Overheat Alarm Level (Pn61B)
• Overheat Warning Level (Pn61C)
• Overheat Alarm Filter Time (Pn61D)
Monitoring the Machine's Temperature and Using Overheat
Protection
Set Pn61A = n.X to 2 or 3 to use overheat protection for the machine.
Set the following parameters as required.
Overheat Alarm Level
Setting Range
Pn61B
Overheat Warning Level
Setting Range
Pn61C
Overheat Alarm Filter Time
Setting Range
Pn61D
When Pn61A is set to n.
line is disconnected or short-circuited.
When Pn61A is set to n.
Important
line is disconnected or short-circuited. To ensure safety, we recommend that you connect the
external circuits so that you can use a negative voltage input for the overheat protection input (an
analog voltage input).
0
Disable overheat protection.
Use overheat protection in the Yaskawa Linear
1
Servomotor.*
Monitor a negative voltage input from a sensor
2
attached to the machine and use overheat pro-
tection.
Monitor a positive voltage input from a sensor
3
attached to the machine and use overheat pro-
tection.
Setting Unit
0 to 500
0.01 V
Setting Unit
0 to 100
1%
Setting Unit
0 to 65,535
1 s

2, an A.862 alarm will occur if the overheat protection input signal

3, an A862 alarm will not occur if the overheat protection input signal

6.12.2 Overheat Protection Selection


Meaning
Default Setting
When Enabled
250
Default Setting
When Enabled
100
Default Setting
When Enabled
0
6.12 Overheat Protection
X (Overheat Protection
When Enabled Classification
After restart
Setup
Classification
Immediately
Setup
Classification
Immediately
Setup
Classification
Immediately
Setup
6
6-41

Hide quick links:

Advertisement

Table of Contents
loading