YASKAWA E-7S SERVOPACK SGD7S Product Manual page 431

E-7-series ac servo drive e-7s servopack command option attachable type with indexer module
Table of Contents

Advertisement

13.3 Program Table Operation
13.3.6 SigmaWin+ Procedures
 POUT (Output Signal)
Specify the signals to output immediately after program step execution is started.
Note: 1. If you want to output the signal at the end of the step, specify POUT as POS = "-" in the next step.
2. It is possible to set a ZONE signal for /POUT5 to /POUT7, but the output is always OFF.
1.
Double-click the cell to edit.
The Output Signal Dialog Box will be displayed.
2.
Select the settings for output signals 0 to 7 in the boxes.
The corresponding terminals are given below.
Output signal 0: /POUT0 terminal
Output signal 1: /POUT1 terminal
Output signal 2: /POUT2 terminal
Output signal 3: /POUT3 terminal
Output signal 4: /POUT4 terminal
Output signal 5: /POUT5 terminal
Output signal 6: /POUT6 terminal
Output signal 7: /POUT7 terminal
Active
Not Active
Same as previous step Continues previous state.
ZONE
3.
Click the OK Button.
This concludes the setting procedure.
13-20
Selection Items
Always ON
Always OFF
Sets the ZONE signal (/Z0 to /Z4) that corresponds
to that digit.
Description
Program Table Notation
A
N
:
Z