This section explains the settings for the INDEXER Module's serial commands.
14.3.1

Block Diagram

The following block diagram shows the basic connections for multi-axis control.
Host
controller
Refer to the following section for information on wiring.
4.6 Serial Command Communications Connector (CN12) on page 4-43
14.3.2

Setting the Axis Address

Axis addresses can be set with parameter Pn010 (axis address selection). Set an axis address
in the range 1 to F. If an address outside this range is set, serial command communications will
not be performed. Refer to the following section for information on the parameter setting meth-
ods.
5.1 Manipulating Parameters (Pn
Note: With the INDEXER Module (NS600) for SGDH SERVOPACKs, axis addresses were set with rotary switches,
but with INDEXER Modules (SGDV-OCA03A) for SGDV SERVOPACKs, axis addresses are set in the parame-
ters.