12.4 Speed/Position Expansion Function Setting
12.4.3 Program Tables, ZONE Tables, and JOG Speed Tables
Serial
Command
DECTsss =
nnnnnnnn
 Read Commands
Serial
Command
POSTsss
SPDTsss
RDSTTsss
RSPDTsss
ACCTsss
DECTsss
ZONE Tables
 Write Commands
Serial Command
ZONEPTzz =
nnnnnnnn
ZONENTzz =
nnnnnnnn
 Read Commands
Serial
Command
ZONEPTzz
ZONENTzz
12-10
PnB54 = 0 (Disable Expansion Mode)
Setting Range
1 ≤ nnnnnnnn ≤ 99,999,999
[1,000 (reference units/min)/ms]
PnB54 = 0 (Disable Expansion Mode)
POST123 = A + 12345678 [CR] [LF]
POST123 = I + 12345678 [CR] [LF]
POST123 = S + 12345678 [CR] [LF]
POST123 = +INFINITE [SP] [CR] [LF]
POST123 = STOP [SP] [SP] [SP] [SP] [SP]
[SP] [CR] [LF]
POST123 = -[SP] [SP] [SP] [SP] [SP] [SP]
[SP] [SP] [SP] [CR] [LF]
SPDT123 = 12345678 [CR] [LF]
RDSTT123 = 12345678 [CR] [LF]
RDSTT123 = -[SP] [SP] [SP] [SP] [SP] [SP]
[SP] [CR] [LF]
RSPDT123 = 12345678 [CR] [LF]
ACCTsss = 12345678 [CR] [LF]
ACCTsss = : [SP] [SP] [SP] [SP] [SP] [SP]
[SP] [CR] [LF]
DECTsss = 12345678 [CR] [LF]
DECTsss = : [SP] [SP] [SP] [SP] [SP] [SP]
[SP] [CR] [LF]
PnB54 = 0 (Disable Expansion Mode)
Setting Range
-99,999,999 ≤ nnnnnnnn ≤
+99,999,999
-99,999,999 ≤ nnnnnnnn ≤
+99,999,999
PnB54 = 0 (Disable Expansion Mode)
ZONEPT123 = +12345678 [CR] [LF]
ZONENT123 = +12345678 [CR] [LF]
PnB54 = 1 (Enable Expansion Mode)
Serial
Command
1 ≤ nnnnnnnnn ≤ 199,999,999
DECTsss =
[1,000 (reference units/min)/ms]
nnnnnnnnn
Display (Acknowledgment)
PnB54 = 1 (Enable Expansion Mode)
POST123 = A + 1234567890 [CR] [LF]
POST123 = I + 1234567890 [CR] [LF]
POST123 = S + 1234567890 [CR] [LF]
POST123 = +INFINITE [SP] [SP] [SP] [CR]
[LF]
POST123 = STOP [SP] [SP] [SP] [SP] [SP]
[SP] [SP] [SP] [CR] [LF]
POST123 = -[SP] [SP] [SP] [SP] [SP] [SP]
[SP] [SP] [SP] [SP] [SP] [CR] [LF]
SPDT123 = 1234567890 [CR] [LF]
RDSTT123 = 1234567890 [CR] [LF]
RDSTT123 = -[SP] [SP] [SP] [SP] [SP] [SP]
[SP] [SP] [SP] [CR] [LF]
RSPDT123 = 1234567890 [CR] [LF]
ACCTsss = 1234567890 [CR] [LF]
ACCTsss = : [SP] [SP] [SP] [SP] [SP] [SP]
[SP] [SP] [SP] [CR] [LF]
DECTsss = 1234567890 [CR] [LF]
DECTsss = : [SP] [SP] [SP] [SP] [SP] [SP]
[SP] [SP] [SP] [CR] [LF]
PnB54 = 1 (Enable Expansion Mode)
Serial Command
ZONEPTzz =
nnnnnnnnnn
ZONENTzz =
nnnnnnnnnn
Display (Acknowledgment)
PnB54 = 1 (Enable Expansion Mode)
ZONEPT123 = +1234567890 [CR] [LF]
ZONENT123 = +1234567890 [CR] [LF]
Continued from previous page.
Setting Range
Setting Range
-1,073,741,823 ≤ nnnnnnnnnn
≤ +1,073,741,823
-1,073,741,823 ≤ nnnnnnnnnn
≤ +1,073,741,823

Hide quick links: