1.2 Introduction to the INDEXER Module
1.2.2 Serial Commands
1.2.2
Serial Commands
With serial commands, ASCII command strings are sent to the INDEXER Module through RS-
422 or RS-485 communications and these commands are interpreted and executed immedi-
ately. You can use general-purpose serial communications (RS422/RS485) to perform indepen-
dent control of up to 16 axes from one host controller (e.g., PC or HMI).
Computer
1SVON
1POSI=400000
1SPD=2000
1ACC=200
1DEC=100
1ST
:
Speed
1-6
# Servo turned ON.
# Set relative position to 400,000.
# Set speed to 2,000.
# Set acceleration rate to 200.
# Set deceleration rate to 100.
# Start operation.
Positioning speed (SPD)
Path when an S-curve filter is set
Target position
(POS)
Acceleration rate (ACC) Deceleration rate (DEC)
RS-422/RS-485, 16 axes max.
Time