Applicable Tools; Operating Procedure - YASKAWA E-7S SERVOPACK SGD7S Product Manual

E-7-series ac servo drive e-7s servopack command option attachable type with indexer module
Table of Contents

Advertisement

7.3 Trial Operation for the Servomotor without a Load

7.3.2 Applicable Tools

7.3.2

Applicable Tools

The following table lists the tools that you can use to perform jog operation and the applicable
tool functions.
Digital Operator
SigmaWin+
7.3.3

Operating Procedure

Use the following procedure for a jog operation.
1.
Click the
2.
Select JOG Operation in the Menu Dialog Box.
The Jog Operation Dialog Box will be displayed.
3.
Read the warnings and then click the OK Button.
4.
Check the jog operation speed and then click the Servo ON Button.
The display in the Operation Area will change to Servo ON.
Information
7-8
Tool
Function
Fn002
Test Run - Jog
Servo Drive Button in the workspace of the Main Window of the SigmaWin+.
To change the speed, click the Edit Button and enter the new speed.
Operating Procedure Reference
Σ-7-Series Digital Operator Operating Manual (Manual
No.: SIEP S800001 33)
Operating Procedure on page 7-8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents