16.2 List of Parameters
16.2.2 List of Parameters
Parameter
No.
PnB05
PnB06
PnB07
PnB08
16-24
Name
2
/PGMRES; /JOGP
• When /MODE signal is ON (closed) (mode 0): Resets and cancels program table opera-
tion by switching the /PGMRES signal from OFF (open) to ON (closed).
0000h
• When /MODE signal is OFF (open) (mode 1): Executes JOG operation in the forward
direction while the /JOGP signal is ON (closed).
• When /MODE signal is ON (closed) (mode 0): Resets and cancels program table opera-
tion by switching the /PGMRES signal from ON (closed) to OFF (open).
0001h
• When /MODE signal is OFF (open) (mode 1): Executes JOG operation in the forward
direction while the /JOGP signal is OFF (open).
• When /MODE signal is ON (closed) (mode 0): Program table operation is not reset.
0002h,
• When /MODE signal is OFF (open) (mode 1): Does not execute JOG operation.
0003h
2
/SEL0; /JOGN
• When /MODE signal is ON (closed) (mode 0): The /SEL0 signal is active when ON
(closed).
0000h
• When /MODE signal is OFF (open) (mode 1): Executes JOG operation in the reverse
direction while the /JOGN signal is ON (closed).
• When /MODE signal is ON (closed) (mode 0): The /SEL0 signal is active when OFF
(open).
0001h
• When /MODE signal is OFF (open) (mode 1): Executes JOG operation in the reverse
direction while the /JOGN signal is OFF (open).
• When /MODE signal is ON (closed) (mode 0): The /SEL0 signal is always active.
0002h
• When /MODE signal is OFF (open) (mode 1): Does not execute JOG operation.
• When /MODE signal is ON (closed) (mode 0): The /SEL0 signal is always inactive.
0003h
• When /MODE signal is OFF (open) (mode 1): Does not execute JOG operation.
2
/SEL1; /JOG0
• When /MODE signal is ON (closed) (mode 0): The /SEL1 signal is active when ON
(closed).
0000h
• When /MODE signal is OFF (open) (mode 1): The /JOG0 signal is active when ON
(closed).
• When /MODE signal is ON (closed) (mode 0): The /SEL1 signal is active when OFF
0001h
(open).
• When /MODE signal is OFF (open) (mode 1): The /JOG0 signal is active when OFF (open).
• When /MODE signal is ON (closed) (mode 0): The /SEL1 signal is always active.
0002h
• When /MODE signal is OFF (open) (mode 1): The /JOG0 signal is always active.
• When /MODE signal is ON (closed) (mode 0): The /SEL1 signal is always inactive.
0003h
• When /MODE signal is OFF (open) (mode 1): The /JOG0 signal is always inactive.
2
/SEL2; /JOG1
• When /MODE signal is ON (closed) (mode 0): The /SEL2 signal is active when ON
(closed).
0000h
• When /MODE signal is OFF (open) (mode 1): The /JOG1 signal is active when ON
(closed).
• When /MODE signal is ON (closed) (mode 0): The /SEL2 signal is active when OFF
0001h
(open).
• When /MODE signal is OFF (open) (mode 1): The /JOG1 signal is active when OFF (open).
• When /MODE signal is ON (closed) (mode 0): The /SEL2 signal is always active.
0002h
• When /MODE signal is OFF (open) (mode 1): The /JOG1 signal is always active.
• When /MODE signal is ON (closed) (mode 0): The /SEL2 signal is always inactive.
0003h
• When /MODE signal is OFF (open) (mode 1): The /JOG1 signal is always inactive.
Setting
Setting
Default
Range
Unit
Setting
0000h to
0000h
0003h
0000h to
0000h
0003h
0000h to
0000h
0003h
0000h to
0000h
0003h
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
All
Setup
restart
After
All
Setup
restart
After
All
Setup
restart
After
All
Setup
restart
Continued on next page.