7.6 Convenient Function to Use during Trial Operation
7.6.1 Program Jog Operation
Information
Related Parameters
Use the following parameters to set the program jog operation pattern. Do not change the set-
tings while the program jog operation is being executed.
• Rotary Servomotors
Pn530
Pn531
Pn533
Pn534
Pn535
Pn536
• Direct Drive Servomotors
Pn530
Pn531
Pn533
Pn534
Pn535
Pn536
7-16
If Pn530 is set to n.0, n.1, n.4, or n.5, you can set Pn536 (Program
Jog Operation Number of Movements) to 0 to perform infinite time operation.
You cannot use infinite time operation if Pn530 is set to n.2 or n.3.
If you perform infinite time operation from the Digital Operator, press the JOG/SVON Key to
turn OFF the servo to end infinite time operation.
Program Jog Operation-Related Selections
Setting Range
Setting Unit
0000 to 0005
Program Jog Operation Travel Distance
Setting Range
Setting Unit
1 to 1,073,741,824
1 reference unit
Program Jog Operation Movement Speed
Setting Range
Setting Unit
1 to 10,000
1 min
Program Jog Operation Acceleration/Deceleration Time
Setting Range
Setting Unit
2 to 10,000
Program Jog Operation Waiting Time
Setting Range
Setting Unit
0 to 10,000
Program Jog Operation Number of Movements
Setting Range
Setting Unit
0 to 1,000
Program Jog Operation-Related Selections
Setting Range
Setting Unit
0000 to 0005
Program Jog Operation Travel Distance
Setting Range
Setting Unit
1 to 1,073,741,824
1 reference unit
Program Jog Operation Movement Speed
Setting Range
Setting Unit
1 to 10,000
0.1 min
Program Jog Operation Acceleration/Deceleration Time
Setting Range
Setting Unit
2 to 10,000
Program Jog Operation Waiting Time
Setting Range
Setting Unit
0 to 10,000
Program Jog Operation Number of Movements
Setting Range
Setting Unit
0 to 1,000
Default Setting
0000
Default Setting
32,768
Default Setting
-1
500
Default Setting
1 ms
100
Default Setting
1 ms
100
Default Setting
1
1
Default Setting
0000
Default Setting
32,768
Default Setting
-1
500
Default Setting
1 ms
100
Default Setting
1 ms
100
Default Setting
1
1
When Enabled
Classification
Immediately
Setup
When Enabled
Classification
Immediately
Setup
When Enabled
Classification
Immediately
Setup
When Enabled
Classification
Immediately
Setup
When Enabled
Classification
Immediately
Setup
When Enabled
Classification
Immediately
Setup
When Enabled
Classification
Immediately
Setup
When Enabled
Classification
Immediately
Setup
When Enabled
Classification
Immediately
Setup
When Enabled
Classification
Immediately
Setup
When Enabled
Classification
Immediately
Setup
When Enabled
Classification
Immediately
Setup

Hide quick links: