13.3 Program Table Operation
13.3.8 Program Table Operation Examples
• Operating Procedure
Turn ON the /MODE 0/1 signal to change to mode 0.
Set the /SEL0 to /SEL7 signals to 3 (i.e., turn ON /SEL0 and /SEL1) to specify program
step 3.
Turn ON the /START-STOP signal to start program table operation.
The /INPOSITION signal turns OFF and the /POUT3 signal turns ON.
When positioning is completed to the target position, the /INPOSITION signal turns ON.
Turn OFF the /START-STOP signal.
Set the /SEL0 to /SEL7 signals to 5 (i.e., turn ON /SEL0 and /SEL2) to specify program
step 5.
Turn ON the /START-STOP signal to start program table operation.
The /POUT5 signal turns ON.
When positioning is completed to the target position, the /INPOSITION signal turns ON.
• Operation Pattern and Related Signal Timing
Operation
Pattern
/MODE 0/1
/START-STOP*
/SEL0 to
/SEL7*
/INPOSITION
/POUT0 to
/POUT7
*
Do not change /SEL0 to /SEL7 for 4 ms after turning ON the /START-STOP signal.
13-28
Speed
Mode 0 (Program Table Operation)
4 ms min.
2 ms min.
Step 3
2 ms min.
3
8
Step 5
0 ms min.
5
32
Time