4.3 Wiring the Power Supply to the SERVOPACK
4.3.5 Wiring Regenerative Resistors
2.
Connect the External Regenerative Resistor between the B1/⊕ and B2 terminals.
3.
Set Pn600 (Regenerative Resistor Capacity) and Pn603 (Regenerative Resistor Resis-
tance).
Refer to the following section for details on the settings.
 SERVOPACK Models SGD7S-470A, -550A, -590A, and -780A
1.
Connect the R1 and R2 terminals on the Regenerative Resistor Unit to the B1/
terminals on the SERVOPACK.
2.
Set Pn600 (Regenerative Resistor Capacity) and Pn603 (Regenerative Resistor Resis-
tance) as required.
• When using the Yaskawa-recommended Regenerative Resistor Unit, use the default settings for
Pn600 and Pn603.
• If you use any other external regenerative resistor, set Pn600 and Pn603 according to the specifica-
tions of the regenerative resistor.
Refer to the following section for details on the settings.
4-24
Enlarged View
5.17 Setting the Regenerative Resistor Capacity on page 5-53
5.17
Setting the Regenerative Resistor Capacity
on page 5-53
and B2