YASKAWA E-7S SERVOPACK SGD7S Product Manual page 611

E-7-series ac servo drive e-7s servopack command option attachable type with indexer module
Table of Contents

Advertisement

16.2 List of Parameters
16.2.2 List of Parameters
Parameter
No.
Pn552
Pn553
Pn55A
Pn560
Pn561
Pn581
Pn582
Pn583
Pn584
Pn585
Pn586
Pn587
Pn600
Pn601
Pn603
Pn604
Pn61A
Pn61B
*14
Pn61C
*14
Pn61D
*14
16-22
Name
Analog Monitor 1 Mag-
2
nification
Analog Monitor 2 Mag-
2
nification
Power Consumption
2
Monitor Unit Time
Residual Vibration
2
Detection Width
Overshoot Detection
2
Level
2
Zero Speed Level
Reserved parameter (Do
2
not change.)
Brake Reference Out-
2
put Speed Level
Speed Limit Level at
2
Servo ON
Program Jog Operation
2
Movement Speed
Motor Running Cooling
2
Ratio
Reserved parameters
2
(Do not change.)
Regenerative Resistor
2
*10
Capacity
Dynamic Brake Resis-
2
tor Allowable Energy
Consumption
Regenerative Resis-
2
tance
Dynamic Brake Resis-
2
tance
Overheat Protection
2
Selections
n.  X
Overheat Protection Selection
0
Disable overheat protection.
1
Use overheat protection in the Yaskawa Linear Servomotor.
Monitor a negative voltage input from a sensor attached to the machine and
2
use overheat protection.
Monitor a positive voltage input from a sensor attached to the machine and
3
use overheat protection.
n.  X 
Reserved parameter (Do not change.)
n.  X 
Reserved parameter (Do not change.)
n.X 
Reserved parameter (Do not change.)
2
Overheat Alarm Level
2
Overheat Warning Level
Overheat Alarm Filter
2
Time
Setting
Setting
Default
Range
Unit
Setting
-10,000 to
× 0.01
100
10,000
-10,000 to
× 0.01
100
10,000
1 to 1,440
1 min
1
1 to 3,000
0.1%
400
0 to 100
1%
100
1 to 10,000
1 mm/s
20
10
0 to 10,000
1 mm/s
10
0 to 10,000
1 mm/s
10000
1 to 10,000
1 mm/s
50
1%/
0 to 100
Max.
0
speed
0000h
Depends on
10 W
0
*11
model.
0 to 65,535
10 J
0
0 to 65,535
10 mΩ
0
0 to 65,535
10 mΩ
0
0000h to
0000h
0003h
0 to 500
0.01 V
250
0 to 100
1%
100
0 to 65,535
1 s
0
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
Linear
Setup
ately
Linear
Immedi-
Linear
Setup
ately
Immedi-
Linear
Setup
ately
Immedi-
Linear
Setup
ately
Immedi-
Linear
Setup
ately
Linear
Immedi-
All
Setup
ately
After
All
Setup
restart
Immedi-
All
Setup
ately
After
All
Setup
restart
After
Linear
Setup
restart
*13
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Continued on next page.
Refer-
ence
page
9-11
page
9-11
page
8-54
page
8-30,
page
8-39
page
1-10
page
5-31
page
8-9
page
7-14
page
5-53
*12
page
5-53
*12
page
6-41
page
6-41
page
6-41
page
6-41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents