15.2 Alarm Displays
15.2.3 INDEXER Module Alarm Displays and Troubleshooting
Serial
Command
Negative
Response
E1BA
E1CA
E1DA
E1EA
E1FA
E21A
E22A
15-46
Alarm
Alarm Name
Number
Program Out-of-
range Alarm
(Detected only
A.AEF
when control
power supply is
turned ON.)
ZONE Table
Checksum Alarm
(Detected only
A.AEF
when control
power supply is
turned ON.)
ZONE Table Ver-
sion Unmatched
(Detected only
A.AEF
when the control
power supply is
turned ON.)
ZONE Table Out-
of-range Alarm
(Detected only
A.AEF
when control
power supply is
turned ON.)
JOG Speed
Table Checksum
Alarm
A.AEF
(Detected only
when control
power supply is
turned ON.)
JOG Speed
Table Version
Unmatched
A.AEF
(Detected only
when the control
power supply is
turned ON.)
JOG Speed
Table Out-of-
range Alarm
A.AEF
(Detected only
when control
power supply is
turned ON.)
Meaning
Corrective Action
• Change the firmware
A value set in the pro-
version.
• Change the program
gram table is not
within the allowed
table version to
setting range.
match the firmware
version.
The ZONE table
stored in flash mem-
• Initialize the ZONE
ory was not recorded
table with the
properly.
ZONEINIT command
(This alarm can occur
or FnB07.
if the control power
• If the problem is not
supply is turned OFF
solved, correct the
while the ZONE table
ZONE table.
is being saved or ini-
tialized.)
• Change the firmware
The combination of
version.
• Change the ZONE
the firmware version
and the ZONE table
table version to
version is wrong.
match the firmware
version.
• Change the firmware
A value set in the
version.
• Change the ZONE
ZONE table is not
within the allowed
table version to
setting range.
match the firmware
version.
The JOG speed table
stored in flash mem-
• Initialize the JOG
ory was not recorded
speed table with the
properly.
JSPDINIT command
(This alarm can occur
or FnB08.
if the control power
• If the problem is not
supply is turned OFF
solved, correct the
while the JOG speed
JOG speed table.
table is being saved
or initialized.)
• Change the firmware
The combination of
version.
the firmware version
• Change the JOG
and the JOG speed
speed table version
table version is
to match the firm-
wrong.
ware version.
• Change the firmware
A value set in the
version.
• Change the JOG
JOG speed table is
not within the allowed
speed table version
setting range.
to match the firm-
ware version.
Continued from previous page.
Servo-
motor
Alarm
Stop
Reset
Method
Gr.1
Available
*2
Gr.1
Available
Gr.1
Available
Gr.1
Available
Gr.1
Available
Gr.1
Available
Gr.1
Available
Continued on next page.
*1
*2
*2
*2
*3
*3
*3