E-7-series ac servo drive e-7s servopack command option attachable type with indexer module
Table of Contents

Advertisement

Changing the Function
Connect the digital operator to the SERVOPACK, and turn ON the power to the SERVOPACK.
The initial display appears, and then the Parameter/Monitoring Function screen appears. Press
the
key to change the function.
Power ON
F i l e l i s t l o a d i n g
P l e a s e w a i t . . . .
− P R M / M O N −
B B
U n 0 0 0 =
0
0 0 0 0 0
U n 0 0 2 =
0
0 0 0 0 0
U n 0 0 8 =
0
0 0 0 0 0 0 0 0 0 0
U n 0 0 D =
0
0 0 0 0 0 0 0 0 0 0
− F U N C T I O N −
B B
F n 0 1 E : V − M o n i t o r
F n 0 0 0 : A l m H i s t o r y
F n 0 0 2 : J O G
F n 0 0 3 : Z − S e a r c h
− C O P Y −
B B
1 : S E R V O → O P
2 : O P → S E R V O
3 : V E R I F Y
4 : L I S T
Reading the Screen
• The SERVOPACK status is always displayed at the top left of the screen (
BB: Base blocked
RUN: Servomotor is ON
A. : Alarm/warning is in effect ( is the alarm/warning code).
PT NT: Forward run and reverse run prohibited (Over travel)
P-OT: Forward run prohibited (Over travel)
N-OT: Reverse run prohibited (Over travel)
P-LS: Forward software limit
N-LS: Reverse software limit
NO-OP: Setting disabled or setting error
HBB: During hard wire base block
• The figure of editing screen used in the program tables, ZONE tables and JOG speed tables
has the following elements.
: The article and table number currently selected
: The article of the table
: The table number
: The table settings
Note: The line beneath POS000 shows that this indication is flashing. This line does not appear on the actual
screen. Note also that the part that flashes is referred to as the cursor in this document.
[Initial Display]
Displayed for two seconds
[Parameter/Monitoring Functions]
Parameter Functions
Sets and displays the internal parameters of the SERVOPACK
and the INDEXER Module.
Monitoring Functions
Shows the numerical values and signal statuses that indicate
the internal data (speed, position and torque) of the SERVOPACK.
The figure to the left shows the Monitoring Function screen.
[Utility Functions]
Sets up the SERVOPACK, adjusts the servo gains, and maintains
the SERVOPACK.
Edits the tables of the INDEXER Module, and performs
INDEXER Module setting, monitoring and maintenance.
[Parameter Copy Functions]
Copies and stores the SERVOPACK parameters settings to the digital
operator, or writes them into the SERVOPACK.
17.2 Operation of Digital Operator