YASKAWA E-7S SERVOPACK SGD7S Product Manual page 540

E-7-series ac servo drive e-7s servopack command option attachable type with indexer module
Table of Contents

Advertisement

Alarm Number:
Possible Cause
Alarm Name
A.8A5:
An overspeed error
was detected in the
External Encoder
external encoder.
Overspeed
A.8A6:
An overheating error
was detected in the
External Encoder
external encoder.
Overheated
A.AEF:
Some kind of alarm
has occurred at the
INDEXER
INDEXER Module.
Module Alarm
A.b33:
A failure occurred in
the current detection
Current Detec-
circuit.
tion Error 3
A.bF0:
A failure occurred in
the SERVOPACK.
System Alarm 0
A.bF1:
A failure occurred in
System Alarm 1
the SERVOPACK.
A.bF2:
A failure occurred in
the SERVOPACK.
System Alarm 2
A.bF3:
A failure occurred in
the SERVOPACK.
System Alarm 3
A.bF4:
A failure occurred in
the SERVOPACK.
System Alarm 4
A.bF5:
A failure occurred in
the SERVOPACK.
System Alarm 5
A.bF6:
A failure occurred in
System Alarm 6
the SERVOPACK.
Confirmation
Check the maximum
Keep the external
speed of the external
encoder below its maxi-
encoder.
mum speed.
Replace the external
encoder.
Use the SigmaWin+ to
Follow the correction for a
check the serial com-
serial command negative
mand negative
response from the
response of the
INDEXER Module.
INDEXER Module.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
15.2 Alarm Displays
15.2.2 Troubleshooting Alarms
Continued from previous page.
Correction
Reference
page 15-44
Continued on next page.
15
15-29