Writing the Jog Speed Table
You can write the edited jog speed table to SERVOPACK RAM to operate the SERVOPACK
according to the program.
1. Make sure that the system is in SERVO OFF state when you write the jog speed table.
2. The jog speed table that is written will be deleted when the power supply to the SERVOPACK
is turned OFF.
Note
Before you turn OFF the power supply to the SERVOPACK, save the jog speed table from
RAM to flash memory. Refer to the following section for the operating procedure.
Saving the Jog Speed Table on page 13-48
1.
Click the Write Button on the Jog Speed Table Editing Dialog Box.
The Write Dialog Box will be displayed.
2.
Click the OK Button.
The jog speed table edited on the SigmaWin+ will be written to the SERVOPACK and the edited cells
will change to white.
13.4 Jog Speed Table Operation