13.5 ZONE Outputs
13.5.3 SigmaWin+ Procedures
Writing the ZONE Table
You can write the edited ZONE table to SERVOPACK RAM to operate the SERVOPACK
according to the program.
Note
1.
Click the Write Button on the Zone Table Editing.
The Write Dialog Box will be displayed.
2.
Click the OK Button.
The ZONE table edited on the SigmaWin+ will be written to the SERVOPACK and the edited cells will
change to white.
13-56
1. Make sure that the system is in SERVO OFF state when you write the ZONE table.
2. The ZONE table that is written will be deleted when the power supply to the SERVOPACK is
turned OFF.
Before you turn OFF the power supply to the SERVOPACK, save the ZONE table from RAM to
flash memory. Refer to the following section for the operating procedure.
Saving the ZONE Table on page 13-58