YASKAWA E-7S SERVOPACK SGD7S Product Manual page 608

E-7-series ac servo drive e-7s servopack command option attachable type with indexer module
Table of Contents

Advertisement

Parameter
Name
No.
Torque Limit at Main Cir-
2
Pn424
cuit Voltage Drop
Release Time for Torque
2
Pn425
Limit at Main Circuit
Voltage Drop
Reserved parameter (Do
2
Pn426
not change.)
Speed Ripple Compen-
2
Pn427
sation Enable Speed
Sweep Torque Refer-
2
Pn456
ence Amplitude
Notch Filter Adjustment
2
Selections 1
Notch Filter Adjustment Selection 1

n.
X
Pn460

n.
X
Reserved parameter (Do not change.)
Notch Filter Adjustment Selection 2

n.
X

n.X
Reserved parameter (Do not change.)
Gravity Compensation-
2
Related Selections
n.  X
Gravity Compensation Selection
Pn475
n.  X 
Reserved parameter (Do not change.)
n.  X 
Reserved parameter (Do not change.)
n.X 
Reserved parameter (Do not change.)
Gravity Compensation
Pn476
2
Torque
Reserved parameter (Do
2
Pn480
not change.)
Polarity Detection
2
Pn481
Speed Loop Gain
Polarity Detection
2
Pn482
Speed Loop Integral
Time Constant
2
Pn483
Forward Force Limit
2
Pn484
Reverse Force Limit
Polarity Detection Refer-
2
Pn485
ence Speed
Setting
Setting
Range
Unit
*3
0 to 100
1%
0 to 1,000
1 ms
0 to 10,000
1 min
1 to 800
1%
0000h to
0101h
Do not adjust the first stage notch filter automatically during execution of auto-
0
tuning without a host reference, autotuning with a host reference, and custom
tuning.
Adjust the first stage notch filter automatically during execution of autotuning
1
without a host reference, autotuning with a host reference, and custom tuning.
Do not adjust the second stage notch filter automatically during execution of
0
autotuning without a host reference, autotuning with a host reference, and
custom tuning.
Adjust the second stage notch filter automatically during execution of autotun-
1
ing without a host reference, autotuning with a host reference, and custom
tuning.
0000h to
0001h
0
Disable gravity compensation.
1
Enable gravity compensation.
-1,000 to
0.1%
1,000
10 to 20,000
0.1 Hz
15 to 51,200 0.01 ms
*3
0 to 800
1%
*3
0 to 800
1%
0 to 100
1 mm/s
16.2.2 List of Parameters
Continued from previous page.
Default
Applicable
When
Setting
Motors
Enabled
Immedi-
50
All
ately
Immedi-
100
All
ately
0
All
Immedi-
-1
0
Rotary
ately
Immedi-
15
All
ately
Immedi-
0101h
All
ately
After
0000h
All
restart
Immedi-
0
All
ately
10000
Linear
Immedi-
400
Linear
ately
Immedi-
3000
Linear
ately
Immedi-
30
Linear
ately
Immedi-
30
Linear
ately
Immedi-
20
Linear
ately
Continued on next page.
16.2 List of Parameters
Classi-
Refer-
fication
ence
page
Setup
6-13
page
Setup
6-13
page
Tuning
8-62
page
Tuning
8-93
page
8-14,
Tuning
page
8-31
page
Setup
8-69
page
Tuning
8-69
Tuning
Tuning
page
Setup
6-22
page
Setup
6-22
Tuning
16-19
16

Hide quick links: