YASKAWA E-7S SERVOPACK SGD7S Product Manual page 539

E-7-series ac servo drive e-7s servopack command option attachable type with indexer module
Table of Contents

Advertisement

15.2 Alarm Displays
15.2.2 Troubleshooting Alarms
Alarm Number:
Alarm Name
A.862:
Overheat Alarm
A.890:
Encoder Scale
Error
A.891:
Encoder Module
Error
A.8A0:
External Encoder
Error
A.8A1:
External Encoder
Module Error
A.8A2:
External Incre-
mental Encoder
Sensor Error
A.8A3:
External Abso-
lute Encoder
Position Error
15-28
Possible Cause
Check the surrounding
The surrounding tem-
temperature using a
perature is too high.
thermostat.
Check the input voltage
The overheat protec-
with the overheat pro-
tion input signal line is
tection input information
disconnected or
on the Motion Monitor
short-circuited.
Tab Page on the
SigmaWin+.
An overload alarm
Check the alarm display
was reset by turning
to see if there is an
OFF the power sup-
overload alarm.
ply too many times.
Operation was per-
Use the accumulated
formed under an
load ratio to check the
excessive load.
load during operation.
A failure occurred in
the SERVOPACK.
The temperature
detection circuit in the
Linear Servomotor is
faulty or the sensor
attached to the
machine is faulty.
A failure occurred in
the linear encoder.
A failure occurred in
the linear encoder.
Setting the origin of
Before you set the ori-
the absolute linear
gin, use the fully-closed
encoder failed
feedback pulse counter
because the motor
to confirm that the
moved.
motor is not moving.
A failure occurred in
the external encoder.
A failure occurred in
the external encoder.
A failure occurred in
the Serial Converter
Unit.
A failure occurred in
the external encoder.
A failure occurred in
the external absolute
encoder.
Confirmation
Lower the surrounding
temperature by improving
the installation conditions
of the Linear Servomotor
or the machine.
Repair the line for the
overheat protection input
signal.
Change the method for
resetting the alarm.
Reconsider the load and
operating conditions.
The SERVOPACK may be
faulty. Replace the
SERVOPACK.
The temperature detec-
tion circuit in the Linear
Servomotor may be faulty
or the sensor attached to
the machine may be
faulty. Replace the Linear
Servomotor or repair the
sensor attached to the
machine.
The linear encoder may
be faulty. Replace the lin-
ear encoder.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the linear encoder
may be faulty. Replace the
linear encoder.
The motor must be
stopped while setting the
origin position.
Replace the external
encoder.
Replace the external
encoder.
Replace the Serial Con-
verter Unit.
Replace the external
encoder.
The external absolute
encoder may be faulty.
Refer to the encoder
manufacturer's instruc-
tion manual for correc-
tions.
Continued from previous page.
Correction
Reference
page 5-50
Continued on next page.

Hide quick links:

Advertisement

Table of Contents
loading