Writing the Program Table
You can write the edited program table to SERVOPACK RAM to operate the SERVOPACK
according to the program table.
1. Make sure that the system is in SERVO OFF state when you write the program table.
2. The program table that is written will be deleted when the power supply to the SERVOPACK is
turned OFF. Before you turn OFF the power supply to the SERVOPACK, save the program
Note
table from RAM to flash memory. Refer to the following section for the procedure.
Saving the Program Table on page 13-24
1.
Click the Write Button in the Program Table Editing Dialog Box.
The Write Dialog Box will be displayed.
2.
Click the OK Button.
The program table edited on the SigmaWin+ will be written to the SERVOPACK and all edited cells
will change to white.
This concludes the writing procedure.
13.3 Program Table Operation
13.3.6 SigmaWin+ Procedures