fast_failover
Use the
fast_failover
controller in 'availability' mode. Use the no form of the command to disable the fast failover feature.
fast_failover | no fast_failover
Parameters
None
Examples
WLC.siemens.com
link_timeout
Use the
link_timeout
Wireless APs and the primary controller in 'availability' mode would be detected.
link_timeout seconds
Parameters
seconds
Examples
The following example sets the time for link failure detection to 10 seconds:
WLC.siemens.com
sync-config
Use the
sync-config
sync-config enable|disable
Parameters
enable
disable
Example
The following example enables the synchronization of the configuration elements:
WLC.siemens.com
SCALANCE WLC711 CLI Reference Guide
command to enable fast failover of the Wireless APs to the secondary
:availability# fast_failover
command to specify the time period in which the link failure between the
Specifies time period in seconds before link failure is detected. Valid values are 2 to
30 seconds.
:availability# link_timeout 10
command to enable or disable synchronization of the configuration elements.
Enable synchronization of the configuration elements.
Disable synchronization of the configuration elements.
:availability# sync-config enable
root Commands
fast_failover