Parameters
enable
disable
Example
The following example enables TXBF on radio1:
WLC.siemens.com
tx_max_power
Use the
tx_max_power
accessible from all ap: radio contexts of the CLI.
tx_max_power value
Parameters
value
Example
The following example sets the maximum Tx power level to 18 dBm:
WLC.siemens.com
tx_min_power
Use the
tx_min_power
command is accessible from the ap:defaults:11n, ap37xx, ap38xx, ap3801, dualband, std, and ap:<serial>
radio1 and radio2 contexts of the CLI. The tx_min_power is available only when Auto Tx Power Ctrl
(ATPC) is enabled.
tx_min_power value
Parameters
value
Example
The following example specifies the minimum Tx power level to 8 dBm:
WLC.siemens.com
SCALANCE WLC711 CLI Reference Guide
Enables the 11n advanced TXBF feature.
Disables the 11n advanced TXBF feature
:ap:defaults:ap37xx:radio1# txbf enable
command to set the maximum Tx power level. The
Specifies the maximum Tx power level.
:ap:defaults:11n:radio2# tx_max_power 18
command to specify the minimum Tx power level. The
Specifies the value in dBm.
:ap:defaults:ap37xx:radio1# tx_min_power 8
ap Commands
tx_max_power
command is
tx_max_power
tx_min_power