atpc no atpc [maintain_power]
Parameters
maintain_power
Example
The following example disables atpc on Radio 1:
WLC.siemens.com
att
Use this command to configure the attenuation for this radio context. The
from all radio1 and radio2 contexts of the CLI.
att att-value
Parameters
att-value
Example
This example sets the attenuation value to 10 for the AP 0409920201204003 radio2 context:
WLC.siemens.com
WLC.siemens.com
beaconp
Use the
command to set time units between beacon transmissions. The
beaconp
accessible from all radio contexts of the CLI.
After you run the
beaconp
beaconp 50-1000
Parameters
50-1000
Example
The following example sets the time between successive beacons to 70 ms on Radio 2:
WLC.siemens.com
SCALANCE WLC711 CLI Reference Guide
When you disable ATPC, you can elect to maintain using the current Tx
power setting ATPC had established.
:ap:defaults:11n:radio1# no atpc maintain_power
Specifies a radio attenuation value between 0 - 30
:ap:0409920201204003:radio2# att 10
:ap:0409920201204003:radio2# apply
command, run the
apply
Specifies the number of time units (milliseconds) between beacon
transmissions.
:ap:defaults:11n:radio2# beaconp 70
command is accessible
att
command to implement the change.