facility

Use the
facility
information to the syslog server. Application logs and service logs cannot use the same log level at the
same time.
facility (application|service|audit|station) (0|1|3|4|5|6)
Parameters
application
service
audit
station
0
1
3
4
5
6
Example
The following example sets the application log level 3 to be sent to the syslog server:
WLC.siemens.com
Successfully updated application logs to 3.
The following example sets the station event log level 2 to be sent to the syslog server:
WLC.siemens.com
Successfully updated station logs to 2.

stationevents

Use the
stationevents
stationevents enable|disable
Parameters
enable
disable
SCALANCE WLC711 CLI Reference Guide
command to send update application, service, audit, and station event log
Specifies that application logs are to be updated.
Specifies that service logs are to be updated.
Specifies that audit logs are to be updated.
Specifies that station event logs are to be updated.
Sends the log with the Emergency severity level to the syslog server.
Sends the log with the Alert severity level to the syslog server.
Sends the log with the Error severity level to the syslog server.
Sends the log with the Warning severity level to the syslog server.
Sends the log with the Notice severity level to the syslog server.
Sends the log with the Info severity level to the syslog server.
:syslog# facility application 3
:syslog# facility station 2
command to turn on or off station event forwarding to the syslog server.
Enables station event logging.
Disables tation event logging.