Siemens scalance WLC711 Reference Manual page 132

Hide thumbs Also See for scalance WLC711:
Table of Contents

Advertisement

Parameters
20
40
80
auto
Example
The following example sets the channel width to 40 MHz:
WLC.siemens.com
n_guardinterval
Use the
n_guardinterval
n_guardinterval
ap:<serial> radio and ap38xx and <serial> contexts of the CLI for those APs that support it.
n_guardinterval short | long
Parameters
short
long
Example
The following example sets the long guard interval:
WLC.siemens.com
n_pbthreshold
Use the
n_pbthreshold
determine which channel width to use when the n_chlwidth is set to auto. The
command is accessible from the ap:defaults:11n, ap37xx, ap38xx, ap3801, and ap:<serial> radio and
ap38xx and <serial> contexts of the CLI for those APs that support it.
n_pbthreshold 0-100
Parameters
0-100
SCALANCE WLC711 CLI Reference Guide
Specifies the channel width as 20 MHz
Specifies the channel width as 40 MHz
Specifies the channel width as 80 MHz (802.11ac radios only)
Specifies that the AP automatically selects the channel width depending upon how busy
the extension channel is. The extension channel threshold is set via the n_pbthreshold
command.
:ap:defaults:11n:radio2# n_chlwidth 40
command to specify the guard interval — short or long. The
command is accessible from the ap:defaults:11n, ap37xx, ap38xx, ap3801, and
Specifies a short guard interval
Specifies a short guard interval
:ap:defaults:11n:radio2# n_guardinterval long
command to specify the extension channel threshold. This value is used to
Specifies the extension channel threshold value as a percentage.
ap Commands
n_guardinterval
n_pbthreshold
132

Advertisement

Table of Contents
loading

Table of Contents