Radio Mode
a
ac-strict
an
anac
b
g
gn
n-strict
bg
bgn
Usage
The minimum basic rate must be lower than or equal to the configured maximum basic data rate and
maximum data rate that clients can operate at while associated with the AP.
Example
This example sets the mode for radio 2 to g, then sets the minimum basic data rate to 12 Mbps:
WLC.siemens.com
WLC.siemens.com
mode
Use the
command to set the radio options for the radio context. The
mode
from all radio contexts of the CLI. Depending on the radio mode you select, some of the radio settings
may not be available for configuration.
Syntax: (11n and ap37xx, radio1)
mode a | an | n-strict
Syntax: (11n and ap37xx, radio2)
mode b | g | gn | n-strict | bg | bgn
Syntax: (dualband)
mode a | b | g | bg
Syntax: (4102 and std, radio2)
mode b | g | bg
SCALANCE WLC711 CLI Reference Guide
Minimum Basic Rates
6 | 12 | 24
6 | 12 | 24 | MCS0,1 | MCS1,1 | MCS2,1 | MCS3,1 | MCS4,1 | MCS5,1 | MCS6,1
| MCS7,1
6 | 12 | 24
6 | 12 | 24
1 | 2 | 5.5 | 11
6 | 12 | 24
6 | 12 | 24
6 | 12 | 24 | MCS0 – MCS7
1 | 2 | 5.5 | 11
1 | 2 | 5.5 | 11
:ap:defaults:11n:radio2# mode g
:ap:defaults:11n:radio2# minbrate 12