HP XP20000/XP24000 Manual page 88

Hp storageworks xp24000/xp20000 remote web console error codes (ae131-96086, may 2011)
Hide thumbs Also See for XP20000/XP24000:
Table of Contents

Advertisement

Table 22 Error Codes — Part Code 0605 (continued)
Part
Error
Code
Number
0605
58332
0605
58406
0605
58407
0605
58408
0605
58409
0605
58410
0605
5841 1
0605
58573
0605
58575
0605
58622
88
Remote Web Console for Storage System Messages and Error Codes
Error Message
The external volume is
blocked.
The Delete Volume operation
cannot be performed to the
volume being used by XP
Continuous Access Journal or
Universal Replicator for
Mainframe.
The Delete Volume operation
cannot be performed to the
journal volume of XP
Continuous Access Journal.
Disconnect Subsystem or
Disconnect Volume cannot be
performed, because the status
of the specified external
volume is Cache Cleanup.
The cache mode cannot be
changed when Disconnect
Subsystem or Disconnect
Volume is in progress.
The cache mode cannot be
changed because bind mode
is set to the specified volume.
The cache modes of the
volumes which compose the
LUSE volume are different.
Set the same cache mode to
the volumes which compose
the LUSE volume.
This function is not supported.
An error occurred while
connecting to the subsystem.
Wait for a while, and then
retry the operation.
The Delete Volume operation
cannot be executed to the
external volumes which
include pool volumes.
Release the pool volume
setting and then retry the
operation.
Recommended Action
Ensure that the external
volume is not blocked, and
then retry the operation.
Release the XP Continuous
Access Journal or Universal
Replicator for Mainframe
pair, and then retry the
operation.
Release the journal volume of
the XP Continuous Access
Journal, and then retry the
operation.
Retry the operation after the
Cache Cleanup of the
external volume completes
successfully.
If Cache Cleanup fails, call
HP technical support.
Put the external volume in
normal status by executing
Check Path & Restore
Volume, and then retry the
operation.
Confirm the setting of the
bind mode by Cache
Residency Manager.
The cache modes of the
volumes that compose the
LUSE volume are different.
Set the same cache mode to
the volumes which compose
the LUSE volume.
Check whether the
DKCMAIN microcode version
and the SVP microcode
version are mismatched.
If this problem persists, call
HP technical support.
Release the pool volume
setting, and then retry the
operation.
Severity
Failure
Level
Level
E
5
E
5
E
5
E
5
E
5
E
5
E
5
E
3
E
6
E
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks xp20000Storageworks xp24000

Table of Contents